100% Original Blood Sugar 70 - UBREATH ® Exhalation analyzer (BA200) – e-Linkcare
100% Original Blood Sugar 70 - UBREATH ® Exhalation analyzer (BA200) – e-Linkcare Detail:
Features:
Chronic airway inflammation is a general feature of some types of asthma, cystic fibrosis (CF), bronchopulmonary dysplasia (BPD), and chronic obstructive pulmonary disease (COPD).
In today’s world, a noninvasive,simple, repeatable, quick, convenient, and relatively low cost test called Fractional exhaled nitric oxide (FeNO), often plays a role to help identify airway inflammation, and thereby support a diagnosis of asthma when there is diagnostic uncertainty.
Fractional concentration of carbon monoxide in exhaled breath (FeCO), similar to FeNO, has been evaluated as a candidate breath biomarker of pathophysiological states, including smoking status, and inflammatory diseases of the lung and other organs.
UBREATH Exhalation analyzer (BA810) is a medical device designed & manufactured by e-LinkCare Meditech to associate with both FeNO and FeCO testing to provide rapid, precise, quantitative measurement in order to assist with clinical diagnosis and management such as asthma and other chonic airway inflammations.
In today’s world, a noninvasive,simple, repeatable, quick, convenient, and relatively low cost test called Fractional exhaled nitric oxide (FeNO), often plays a role to help identify airway inflammation, and thereby support a diagnosis of asthma when there is diagnostic uncertainty.
ITEM | Measurement | Reference |
FeNO50 | Fixed Exhale flow level of 50ml/s | 5-15ppb |
FeNO200 | Fixed Exhale flow level of 200ml/s | <10 ppb |
In the meantime, BA200 also provides data for the following parameters
ITEM | Measurement | Reference |
CaNO | Concentration of NO in the gas phase of the alveolar | <5 ppb |
FnNO | Nasal nitric oxide | 250-500 ppb |
FeCO | Fractional concentration of carbon monoxide in exhaled breath | 1-4ppm>6 ppm (if smoking) |
Product detail pictures:
Related Product Guide:
Our firm since its inception, normally regards item top quality as company life, constantly make improvements to generation technology, improve product excellent and repeatedly strengthen organization total good quality management, in strict accordance with the national standard ISO 9001:2000 for 100% Original Blood Sugar 70 - UBREATH ® Exhalation analyzer (BA200) – e-Linkcare , The product will supply to all over the world, such as: Uruguay, Birmingham, Canada, Our domestic website's generated over 50, 000 purchasing orders every year and quite successful for internet shopping in Japan. We would be happy to have an opportunity to do business with your company. Looking forward to receiving your message !
By Erica from United States - 2018.09.29 13:24
The goods are very perfect and the company sales manager is warmful, we will come to this company to purchase next time.
By Helen from Amman - 2017.09.29 11:19