2021 Latest Design A1c Average Glucose - UBREATH ® Spirometer System (PF680) – e-Linkcare
2021 Latest Design A1c Average Glucose - UBREATH ® Spirometer System (PF680) – e-Linkcare Detail:
Measurable Spirometry through Inhale & Exhale
FVC, SVC, MVV are available with 23 parameters to be calculated.
Accuracy and repeatability comply with ATS/ERS task force standardization (ISO26782:2009)
Complies with the ATS/ERS requirement for flow sensitivity down to 0.025L/s which is a vital characteristic for the diagnosis and monitoring of COPD patients.
Real-time Graphic Curve Experience
Synchronized graphs enhance users to achieve satisfied results with professional’s guidance.
Displayed three waveform parameters and remark the best performance for reference.
Portable Design
Hand-held device and easy to operation.
Automated BTPS calibration and free of environmental conditions influence.
Lightweight combines the benefits of portability.
Operate with Safety
Assured hygiene with disposable pneumotach gives NO authority to cross-contamination.
Patented design offers prevention.
Automated quality control and correction algorithm to minimize interference from operation.
All-in-One Service Station
Built-in printer and barcode scanner are combined in one device.
LIS/HIS connection via Wi-Fi and HL7.
Technical Specifications
Feature | Specification |
Model | PF680 |
Parameter | FVC: FVC, FEV1, FEV1%, PEF, FEF25, FEF50, FEF75VC: VC, VT, IRV, ERV, IC MVV: MVV, VT, RR |
Flow Detection Principle | Pneumotachograph |
Volume Range | Volume: (0.5-8) LFlow: (0-14) L/s |
Performance Standard | ATS/ERS 2005 & ISO 26783:2009 |
Volume Accuracy | ±3% or ±0.050L (take the larger value) |
Power Supply | 3.7 V lithium battery (rechargeable) |
Printer | Built-in thermal printer |
Operating Temperature | 10℃ - 40℃ |
Operating Relative Humidity | ≤ 80% |
Size | Spirometer: 133x82x68 mmSensor Handle: 82x59x33 mm |
Weight | 575g (including the Flow Transducer) |
Product detail pictures:

Related Product Guide:
We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of 2021 Latest Design A1c Average Glucose - UBREATH ® Spirometer System (PF680) – e-Linkcare , The product will supply to all over the world, such as: Guyana, Pakistan, Brasilia, We have a good reputation for stable quality products, well received by customers at home and abroad. Our company would be guided by the idea of "Standing in Domestic Markets, Walking into International Markets". We sincerely hope that we could do business with car manufacturers, auto part buyers and the majority of colleagues both at home and abroad. We expect sincere cooperation and common development!