China New Product Dr Trust Portable Nebulizer - ACCUGENCE ® Multi-Monitoring System (PM 800) – e-Linkcare Detail:
Feature |
Specification |
Parameter |
Blood Glucose, Blood β-Ketone, and Blood Uric Acid |
Measurement Range |
Blood Glucose: 0.6 – 33.3 mmol/L (10 – 600 mg/dL) |
Blood β-Ketone: 0.0 – 8.0 mmol/L |
|
Uric Acid: 3.0 – 20.0 mg/dL (179 – 1190 μmol/L) |
|
Hemoglobin: 3.0-26.0 g/dL (1.9-16.1mmol/L) |
|
Hematocrit Range |
Blood Glucose and β-Ketone: 15% – 70 % |
Uric Acid: 25% – 60% |
|
Sample |
When testing β-Ketone, Uric Acid or Blood glucose with Glucose Dehydrogenase FAD-Dependent, use fresh capillary whole blood and venous Blood samples; |
When testing Blood glucose with Glucose Oxidase: use fresh capillary whole blood |
|
Minimum Sample Size |
Hemoglobin: 1.2 μL |
Blood Glucose: 0.7 μL |
|
Blood β-Ketone: 0.9 μL |
|
Blood Uric Acid: 1.0 μL |
|
Test Time |
Hemoglobin: 15 seconds |
Blood Glucose: 5 seconds |
|
Blood β-Ketone: 5 seconds |
|
Blood Uric Acid: 15 seconds |
|
Units of Measure |
Blood Glucose: The meter is preset to either millimole per liter (mmol/L) or milligrams per deciliter (mg/dL) depending on the standard of your country. |
Blood β-Ketone: The meter is preset to millimole per liter (mmol/L) |
|
Blood Uric Acid: The meter is preset to either micromole per liter (μmol/L) or milligrams per deciliter (mg/dL) depending on the standard of your country. |
|
Hemoglobin: the meter is preset to either to millimole per liter (mmol/L) or grams per deciliter (g/dL) depending on the standard of your country. | |
Memory |
Hemoglobin: 200 tests |
Blood Glucose: 500 tests (GOD + GDH) |
|
Blood β-Ketone: 100 tests |
|
Blood Uric Acid: 100 tests |
|
Automatic Shutoff |
2 minutes |
Meter Size |
86 mm × 52 mm × 18 mm |
On/Off Source |
Two CR 2032 3.0V coin cell batteries |
Battery Life |
Around 1000 tests |
Display Size |
32 mm × 40 mm |
Weight |
53 g (with battery installed) |
Operating Temperature |
Glucose and Ketone: 5 – 45 ºC (41 – 113ºF) |
Uric Acid: 10 – 40 ºC (50 – 104ºF) |
|
Operating Relative Humidity |
10 – 90% (non-condensing) |
Operating Altitude |
0 – 10000 feet (0 – 3048 meters) |
Product detail pictures:

Related Product Guide:
Our merchandise are commonly recognized and reliable by customers and can meet constantly developing economic and social desires for China New Product Dr Trust Portable Nebulizer - ACCUGENCE ® Multi-Monitoring System (PM 800) – e-Linkcare , The product will supply to all over the world, such as: Plymouth, Buenos Aires, Australia, Since always, we adhering to the "open and fair, share to get, the pursuit of excellence, and creation of value"values, adhere to the"integrity and efficient, trade-oriented, best way , best valve" business philosophy. Together with our all over the world have branches and partners to develop new business areas, maximum common values. We sincerely welcome and together we share in global resources, opening up new career together with the chapter.