Factory directly supply A1c 5.7 Average Blood Sugar - UBREATH ® Exhalation analyzer (BA200) – e-Linkcare Detail:
Features:
Chronic airway inflammation is a general feature of some types of asthma, cystic fibrosis (CF), bronchopulmonary dysplasia (BPD), and chronic obstructive pulmonary disease (COPD).
In today’s world, a noninvasive,simple, repeatable, quick, convenient, and relatively low cost test called Fractional exhaled nitric oxide (FeNO), often plays a role to help identify airway inflammation, and thereby support a diagnosis of asthma when there is diagnostic uncertainty.
Fractional concentration of carbon monoxide in exhaled breath (FeCO), similar to FeNO, has been evaluated as a candidate breath biomarker of pathophysiological states, including smoking status, and inflammatory diseases of the lung and other organs.
UBREATH Exhalation analyzer (BA810) is a medical device designed & manufactured by e-LinkCare Meditech to associate with both FeNO and FeCO testing to provide rapid, precise, quantitative measurement in order to assist with clinical diagnosis and management such as asthma and other chonic airway inflammations.
In today’s world, a noninvasive,simple, repeatable, quick, convenient, and relatively low cost test called Fractional exhaled nitric oxide (FeNO), often plays a role to help identify airway inflammation, and thereby support a diagnosis of asthma when there is diagnostic uncertainty.
ITEM | Measurement | Reference |
FeNO50 | Fixed Exhale flow level of 50ml/s | 5-15ppb |
FeNO200 | Fixed Exhale flow level of 200ml/s | <10 ppb |
In the meantime, BA200 also provides data for the following parameters
ITEM | Measurement | Reference |
CaNO | Concentration of NO in the gas phase of the alveolar | <5 ppb |
FnNO | Nasal nitric oxide | 250-500 ppb |
FeCO | Fractional concentration of carbon monoxide in exhaled breath | 1-4ppm>6 ppm (if smoking) |
Product detail pictures:
Related Product Guide:
We retain bettering and perfecting our goods and service. At the same time, we perform actively to do research and enhancement for Factory directly supply A1c 5.7 Average Blood Sugar - UBREATH ® Exhalation analyzer (BA200) – e-Linkcare , The product will supply to all over the world, such as: Puerto Rico, Bogota, Ghana, Due to the changing trends in this field, we involve ourselves into products trade with dedicated efforts and managerial excellence. We maintain timely delivery schedules, innovative designs, quality and transparency for our customers. Our moto is to deliver quality products within stipulated time.