Good quality Diabetic Patient - UBREATH ® Spirometer System (PF680) – e-Linkcare
Good quality Diabetic Patient - UBREATH ® Spirometer System (PF680) – e-Linkcare Detail:
Measurable Spirometry through Inhale & Exhale
FVC, SVC, MVV are available with 23 parameters to be calculated.
Accuracy and repeatability comply with ATS/ERS task force standardization (ISO26782:2009)
Complies with the ATS/ERS requirement for flow sensitivity down to 0.025L/s which is a vital characteristic for the diagnosis and monitoring of COPD patients.
Real-time Graphic Curve Experience
Synchronized graphs enhance users to achieve satisfied results with professional’s guidance.
Displayed three waveform parameters and remark the best performance for reference.
Portable Design
Hand-held device and easy to operation.
Automated BTPS calibration and free of environmental conditions influence.
Lightweight combines the benefits of portability.
Operate with Safety
Assured hygiene with disposable pneumotach gives NO authority to cross-contamination.
Patented design offers prevention and no daily sterilization is required.
Automated quality control and correction algorithm to minimize interference from operation.
All-in-One Service Station
Built-in printer and barcode scanner are combined in one device.
LIS/HIS connection via Wi-Fi and HL7.
Technical Specifications
Feature | Specification |
Model | PF680 |
Parameter | FVC: FVC, FEV1, FEV1%, PEF, FEF25, FEF50, FEF75VC: VC, VT, IRV, ERV, IC MVV: MVV, VT, RR |
Flow Detection Principle | Pneumotachograph |
Volume Range | Volume: (0.5-8) LFlow: (0-14) L/s |
Performance Standard | ATS/ERS 2005 & ISO 26783:2009 |
Volume Accuracy | ±3% or ±0.050L (take the larger value) |
Power Supply | 3.7 V lithium battery (rechargeable) |
Printer | Built-in thermal printer |
Operating Temperature | 10℃ - 40℃ |
Operating Relative Humidity | ≤ 80% |
Size | Spirometer: 133x82x68 mmSensor Handle: 82x59x33 mm |
Weight | 575g (including the Flow Transducer) |
Product detail pictures:
Related Product Guide:
Innovation, quality and reliability are the core values of our company. These principles today more than ever form the basis of our success as an internationally active mid-size company for Good quality Diabetic Patient - UBREATH ® Spirometer System (PF680) – e-Linkcare , The product will supply to all over the world, such as: Salt Lake City, Kenya, moldova, Each year, many of our customers would visit our company and achieve great business advancements working with us. We sincerely welcome you to visit us at any time and together we will prevail to a greater success in the hair industry.
By Penny from Iran - 2017.10.13 10:47
In China, we have many partners, this company is the most satisfying to us, reliable quality and good credit, it is worth appreciation.
By Molly from Sri Lanka - 2018.06.26 19:27