High Performance Vixone - ACCUGENCE ® Multi-Monitoring System (PM 900) – e-Linkcare
High Performance Vixone - ACCUGENCE ® Multi-Monitoring System (PM 900) – e-Linkcare Detail:
Advanced Features
Specification
Feature |
Specification |
Parameter |
Blood Glucose, Blood β-Ketone, and Blood Uric Acid |
Measurement Range |
Blood Glucose: 0.6 – 33.3 mmol/L (10 – 600 mg/dL) |
Blood β-Ketone: 0.0 – 8.0 mmol/L |
|
Uric Acid: 3.0 – 20.0 mg/dL (179 – 1190 μmol/L) |
|
Hematocrit Range |
Blood Glucose and β-Ketone: 15% – 70 % |
Uric Acid: 25% – 60% |
|
Sample |
When testing β-Ketone, Uric Acid or Blood glucose with Glucose Dehydrogenase FAD-Dependent, use fresh capillary whole blood and venous Blood samples; |
When testing Blood glucose with Glucose Oxidase: use fresh capillary whole blood |
|
Minimum Sample Size |
Blood Glucose: 0.7 μL |
Blood β-Ketone: 0.9 μL |
|
Blood Uric Acid: 1.0 μL |
|
Test Time |
Blood Glucose: 5 seconds |
Blood β-Ketone: 5 seconds |
|
Blood Uric Acid: 15 seconds |
|
Units of Measure |
Blood Glucose:The meter is preset to either millimole per liter (mmol/L) or milligrams per deciliter (mg/dL) depending on the standard of your country. |
Blood β-Ketone: The meter is preset to millimole per liter (mmol/L) |
|
Blood Uric Acid:The meter is preset to either micromoles per liter (μmol/L) or milligrams per deciliter (mg/dL) depending on the standard of your country. |
|
Memory |
Blood Glucose: 500 tests (GOD + GDH) |
Blood β-Ketone: 100 tests |
|
Blood Uric Acid: 100 tests |
|
Automatic Shutoff |
2 minutes |
Meter Size |
86 mm × 52 mm × 18 mm |
On/Off Source |
Two CR 2032 3.0V coin cell batteries |
Battery Life |
Around 1000 tests |
Display Size |
32 mm × 40 mm |
Weight |
53 g (with battery installed) |
Operating Temperature |
Glucose and Ketone: 5 – 45 ºC (41 – 113ºF) |
Uric Acid: 10 – 40 ºC (50 – 104ºF) |
|
Operating Relative Humidity |
10 – 90% (non-condensing) |
Operating Altitude |
0 – 10000 feet (0 – 3048 meters) |
Product detail pictures:
Related Product Guide:
We will devote ourselves to giving our esteemed buyers using the most enthusiastically thoughtful services for High Performance Vixone - ACCUGENCE ® Multi-Monitoring System (PM 900) – e-Linkcare , The product will supply to all over the world, such as: Los Angeles, Zambia, Irish, We welcome you to visit our company and factory. It is also convenient to visit our website. Our sales team will offer you the best service. If you need more information, please feel free to contact us by E-mail or telephone. We are sincerely hope to establish a good long-term business relationship with you through this opportunity, based on equal, mutual benefit from now till the future.