Advanced Features:
4 in 1 Multi-Function
Underdose Detection
New Enzyme Technology
Wide HCT Range
Small blood sample volume
Wide operating temperature
Comprehensive quality control
Reliable result
Clinical proven performance
Full Compliance ISO 15197: 2013 / EN ISO 15197:2015
Technical Specifications
|
PM910 |
Feature |
Specification |
Parameter |
Blood Glucose, Blood β-Ketone, and Blood Uric Acid |
Measurement Range |
Blood Glucose: 0.6 – 33.3 mmol/L (10 – 600 mg/dL) |
Blood β-Ketone: 0.0 – 8.0 mmol/L |
|
Uric Acid: 3.0 – 20.0 mg/dL (179 – 1190 μmol/L) |
|
Hematocrit Range |
Blood Glucose and β-Ketone: 10% – 70 % |
Uric Acid: 25% – 60% |
|
Sample |
When testing β-Ketone, Uric Acid or Blood glucose with Glucose Dehydrogenase |
When testing Blood glucose with Glucose Oxidase: use fresh capillary whole blood |
|
Minimum Sample Size |
Blood Glucose: 0.7 μL |
Blood β-Ketone: 0.9 μL |
|
Blood Uric Acid: 1.0 μL |
|
Test Time |
Blood Glucose: 5 seconds |
Blood β-Ketone: 5 seconds |
|
Blood Uric Acid: 15 seconds |
|
Units of Measure |
Blood Glucose: |
The meter is preset to either millimole per liter (mmol/L) or milligrams per |
|
Blood β-Ketone:The meter is preset to millimole per liter (mmol/L) |
|
Blood Uric Acid:The meter is preset to either micromoles per liter (μmol/L) or |
|
Memory |
Blood Glucose +β-Ketone+ Uric acid = 150 tests |
Automatic Shutoff |
2 minutes |
Meter Size |
79 mm × 50 mm × 14.5 mm |
On/Off Source |
One CR 2032 3.0V coin cell batteries |
Battery Life |
Around 500 tests |
Display Size |
30 mm × 32 mm |
Weight |
36 g (with battery installed) |
Operating Temperature |
Glucose and Ketone: 5 – 45 ºC (41 – 113ºF) |
Operating Relative Humidity |
Uric Acid: 10 – 40 ºC (50 – 104ºF) |
10 – 90% (non-condensing) |
|
Operating Altitude |
0 – 10000 feet (0 – 3048 meters) |
Product detail pictures:
Related Product Guide:
Adhering to the principle of "quality, service, efficiency and growth", we have gained trusts and praises from domestic and international client for Low MOQ for Mini Nebuliser - ACCUGENCE ® LITE Multi-Monitoring System (PM 910) – e-Linkcare , The product will supply to all over the world, such as: America, New Orleans, Costa Rica, Our company has always insisted on the business principle of "Quality, Honest, and Customer First" by which we have won the trust of clients both from at home and abroad. If you are interested in our solutions, you should do not hesitate to contact us for further information.