carry on to further improve, to guarantee merchandise high-quality in line with market and buyer standard necessities. Our organization has a top quality assurance procedure have already been established for Normal Insulin Level , Levels Glucose Monitor , Fasting Glucose 110 , Objects won certifications together with the regional and international primary authorities. For far a lot more detailed information, make sure you make contact with us!
Professional Design Continuous Blood Glucose Monitor - UBREATH ® Exhalation analyzer (BA200) – e-Linkcare Detail:

Features:

Chronic airway inflammation is a general feature of some types of asthma, cystic fibrosis (CF), bronchopulmonary dysplasia (BPD), and chronic obstructive pulmonary disease (COPD).
In today’s world, a noninvasive,simple, repeatable, quick, convenient, and relatively low cost test called Fractional exhaled nitric oxide (FeNO), often plays a role to help identify airway inflammation, and thereby support a diagnosis of asthma when there is diagnostic uncertainty.

Fractional concentration of carbon monoxide in exhaled breath (FeCO), similar to FeNO, has been evaluated as a candidate breath biomarker of pathophysiological states, including smoking status, and inflammatory diseases of the lung and other organs.

UBREATH Exhalation analyzer (BA810) is a medical device designed & manufactured by e-LinkCare Meditech to associate with both FeNO and FeCO testing to provide rapid, precise, quantitative measurement in order to assist with clinical diagnosis and management such as asthma and other chonic airway inflammations.

In today’s world, a noninvasive,simple, repeatable, quick, convenient, and relatively low cost test called Fractional exhaled nitric oxide (FeNO), often plays a role to help identify airway inflammation, and thereby support a diagnosis of asthma when there is diagnostic uncertainty.

ITEM Measurement Reference
FeNO50  Fixed Exhale flow level of 50ml/s 5-15ppb
FeNO200  Fixed Exhale flow level of 200ml/s <10 ppb

In the meantime, BA200 also provides data for the following parameters

ITEM Measurement Reference
CaNO Concentration of NO in the gas phase of the alveolar <5 ppb
FnNO Nasal nitric oxide 250-500 ppb
FeCO Fractional concentration of carbon monoxide in exhaled breath 1-4ppm>6 ppm (if smoking)

Product detail pictures:

Professional Design Continuous Blood Glucose Monitor - UBREATH ® Exhalation analyzer (BA200)  – e-Linkcare detail pictures


Related Product Guide:

No matter new buyer or old purchaser, We believe in long expression and trusted relationship for Professional Design Continuous Blood Glucose Monitor - UBREATH ® Exhalation analyzer (BA200) – e-Linkcare , The product will supply to all over the world, such as: Paraguay, Maldives, Botswana, Customer satisfaction is our first goal. Our mission is to pursue the superlative quality, making continual progress. We sincerely welcome you to make progress hand in hand with us, and construct a prosperous future together.
  • The customer service staff's attitude is very sincere and the reply is timely and very detailed, this is very helpful for our deal,thank you.
    5 Stars By Gabrielle from Libya - 2018.12.11 14:13
    We have worked with many companies, but this time is the best,detailed explanation, timely delivery and quality qualified, nice!
    5 Stars By Lorraine from Singapore - 2017.06.25 12:48
    Write your message here and send it to us