Special Design for Medel Family Nebulizer - ACCUGENCE ® LITE Multi-Monitoring System (PM 910) – e-Linkcare

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our personnel are generally in the spirit of "continuous improvement and excellence", and together with the outstanding top quality merchandise, favorable price tag and fantastic after-sales solutions, we try to gain every single customer's rely on for Impaired Fasting Glucose , Best Blood Sugar Level , Glucometer , The principle of our company is to provide high-quality products, professional service, and honest communication. Welcome all friends to place trial order for creating a long-term business relationship.
Special Design for Medel Family Nebulizer - ACCUGENCE ® LITE Multi-Monitoring System (PM 910) – e-Linkcare Detail:

Advanced Features:
4 in 1 Multi-Function
Underdose Detection
New Enzyme Technology
Wide HCT Range
Small blood sample volume
Wide operating temperature
Comprehensive quality control
Reliable result
Clinical proven performance
Full Compliance ISO 15197: 2013 / EN ISO 15197:2015

Technical Specifications

 

PM910

Feature

Specification

Parameter

Blood Glucose, Blood β-Ketone, and Blood Uric Acid

Measurement Range

Blood Glucose: 0.6 – 33.3 mmol/L (10 – 600 mg/dL)

Blood β-Ketone: 0.0 – 8.0 mmol/L

Uric Acid: 3.0 – 20.0 mg/dL (179 – 1190 μmol/L)

Hematocrit Range

Blood Glucose and β-Ketone: 10% – 70 %

Uric Acid: 25% – 60%

Sample

When testing β-Ketone, Uric Acid or Blood glucose with Glucose Dehydrogenase
FAD-Dependent, use fresh capillary whole blood and venous Blood samples;

When testing Blood glucose with Glucose Oxidase: use fresh capillary whole blood

Minimum Sample Size

Blood Glucose: 0.7 μL

Blood β-Ketone: 0.9 μL

Blood Uric Acid: 1.0 μL

Test Time

Blood Glucose: 5 seconds

Blood β-Ketone: 5 seconds

Blood Uric Acid: 15 seconds

Units of Measure

Blood Glucose:

The meter is preset to either millimole per liter (mmol/L) or milligrams per
deciliter (mg/dL) depending on the standard of your country.

Blood β-Ketone:The meter is preset to millimole per liter (mmol/L)

Blood Uric Acid:The meter is preset to either micromoles per liter (μmol/L) or
milligrams per deciliter (mg/dL) depending on the standard of your country.

Memory

Blood Glucose +β-Ketone+ Uric acid = 150 tests

Automatic Shutoff

2 minutes

Meter Size

79 mm × 50 mm × 14.5 mm

On/Off Source

One CR 2032 3.0V coin cell batteries

Battery Life

Around 500 tests

Display Size

30 mm × 32 mm

Weight

36 g (with battery installed)

Operating Temperature

Glucose and Ketone: 5 – 45 ºC (41 – 113ºF)

Operating Relative Humidity

Uric Acid: 10 – 40 ºC (50 – 104ºF)

10 – 90% (non-condensing)

Operating Altitude

0 – 10000 feet (0 – 3048 meters)


Product detail pictures:

Special Design for Medel Family Nebulizer - ACCUGENCE ® LITE Multi-Monitoring System (PM 910) – e-Linkcare detail pictures

Special Design for Medel Family Nebulizer - ACCUGENCE ® LITE Multi-Monitoring System (PM 910) – e-Linkcare detail pictures


Related Product Guide:

The customer satisfaction is our primary goal. We uphold a consistent level of professionalism, quality, credibility and service for Special Design for Medel Family Nebulizer - ACCUGENCE ® LITE Multi-Monitoring System (PM 910) – e-Linkcare , The product will supply to all over the world, such as: Hamburg, Peru, Sacramento, So far our merchandise have been exported to east Europe, the Middle East, Southeast, Africa and South America etc. We have now 13years experienced sales and purchase in Isuzu parts at home and abroad and the ownership of the modernized electronic Isuzu parts checking systems. We honor our core principal of Honesty in business, priority in service and will do our best to provide our customers with high quality items and excellent service.
  • A good manufacturers, we have cooperated twice, good quality and good service attitude.
    5 Stars By Albert from Azerbaijan - 2017.02.18 15:54
    The manufacturer gave us a big discount under the premise of ensuring the quality of products, thank you very much, we will select this company again.
    5 Stars By Andrew Forrest from Moscow - 2018.12.05 13:53
    Write your message here and send it to us